Sorry, I totally missed the version: flink-1.6.4, Streaming API
Il giorno ven 14 giu 2019 alle ore 11:08 Chesnay Schepler <[hidden email]> ha scritto:
Which version of Flink are you using? There were some issues at some point about double-counting.
On 14/06/2019 09:49, Andrea Spina wrote:
Dear Community, I'd like to ask for some details about bytes related metrics in Flink. Precisely, I'm looking at bytes sent and bytes received metrics: what I am recording is the following:
I am reading from a Kafka topic A records with schema K using a source Sin belonging to a pipeline P1. The topic A is filled with K data using a separated pipeline p2 and a sink Sout.
Basically what I register is that the bytes sent metric of Sin - available through the Flink UI -measure twice or more respect of the bytes received of Sout. For instance, if my sink Sout records 10GB of bytes received inbound, then my source Sin emits between 20-25GB bytes sent.
--
Is someone able to detail how these two metrics are calculated?
Thank you,
Andrea Spina
Software Engineer @ Radicalbit Srl
Via Borsieri 41, 20159, Milano - IT
--
Andrea Spina
Head of R&D @ Radicalbit Srl
Via Giovanni Battista Pirelli 11, 20124, Milano - IT
Free forum by Nabble | Edit this page |