Re: Flink CEP questions
Posted by
Kostas Kloudas on
URL: http://deprecated-apache-flink-user-mailing-list-archive.369.s1.nabble.com/Flink-CEP-questions-tp14971p14972.html
Hi Basanth,
For:
3) you should use the times(N) and the within(TIME) clauses
4) if by continuously you mean without stopping, then you should use the followedBy() or next()
I am not aware of any examples but you can check this slides:
for an overview of the CEP library or you can watch the related video.
Cheers,
Kostas
All,
New to Flink and more so with Flink CEP.
I want to write a sample program that does the following :
Lets suppose data cpu usage of a given server.
- Want to Alert when CPU usage is above or below certain value
- Want to Alert when CPU usage falls in a range
- Want to Alert when the above condition matches n times in x interval (could be seconds, minutes, hours)
- Want to Alert when the above condition happens continuously for x interval (could be seconds, minutes or hours)
How would we achieve 3, 4 in the list above ? Any examples that I refer to ?
thank you,
Basanth