can flink sql handle udf-generated timestamp field

Yu Yang
Hi, 

I am trying to use Flink SQL to do aggregation on a hopping window. In the data stream, we store the timestamp in long type. So I wrote a UDF 'FROM_UNIXTIME' to convert long to Timestamp type. 

  public static class TimestampModifier extends ScalarFunction {
    public Timestamp eval(long t) {
      return new Timestamp(t);
    }
    public TypeInformation<?> getResultType(Class<?>[] signature) {
      return Types.SQL_TIMESTAMP;
    }
  }

With the above UDF, I wrote the following query, and ran into  "ProgramInvocationException: The main method caused an error: Window can only be defined over a time attribute column". 
Any suggestions on how to resolve this issue? I am using Flink 1.8 for this experiment. 

my sql query: 

select  keyid, sum(value) 
from ( 
   select FROM_UNIXTIME(timestampMs) as ts, key.id as keyid, value 
   from orders) 
 group by HOP(ts, INTERVAL ‘10’ second, INTERVAL ‘30’ second), keyid 

flink exception: 

org.apache.flink.client.program.ProgramInvocationException: The main method caused an error: Window can only be defined over a time attribute column.
at org.apache.flink.client.program.PackagedProgram.callMainMethod(PackagedProgram.java:546)
at org.apache.flink.client.program.PackagedProgram.invokeInteractiveModeForExecution(PackagedProgram.java:421)
at org.apache.flink.client.program.ClusterClient.run(ClusterClient.java:423)
at org.apache.flink.client.cli.CliFrontend.executeProgram(CliFrontend.java:813)
at org.apache.flink.client.cli.CliFrontend.runProgram(CliFrontend.java:287)
at org.apache.flink.client.cli.CliFrontend.run(CliFrontend.java:213)
at org.apache.flink.client.cli.CliFrontend.parseParameters(CliFrontend.java:1050)
at org.apache.flink.client.cli.CliFrontend.lambda$main$11(CliFrontend.java:1126)
at org.apache.flink.runtime.security.NoOpSecurityContext.runSecured(NoOpSecurityContext.java:30)
at org.apache.flink.client.cli.CliFrontend.main(CliFrontend.java:1126)
Caused by: org.apache.flink.table.api.ValidationException: Window can only be defined over a time attribute column.
at org.apache.flink.table.plan.rules.datastream.DataStreamLogicalWindowAggregateRule.getOperandAsTimeIndicator$1(DataStreamLogicalWindowAggregateRule.scala:85)
at org.apache.flink.table.plan.rules.datastream.DataStreamLogicalWindowAggregateRule.translateWindowExpression(DataStreamLogicalWindowAggregateRule.scala:99)
at org.apache.flink.table.plan.rules.common.LogicalWindowAggregateRule.onMatch(LogicalWindowAggregateRule.scala:66)
at org.apache.calcite.plan.AbstractRelOptPlanner.fireRule(AbstractRelOptPlanner.java:319)
at org.apache.calcite.plan.hep.HepPlanner.applyRule(HepPlanner.java:559)
at org.apache.calcite.plan.hep.HepPlanner.applyRules(HepPlanner.java:418)

Regards, 
-Yu
Reply | Threaded
Open this post in threaded view
|

Re: can flink sql handle udf-generated timestamp field

JingsongLee
Hi @Yu Yang:
Time-based operations such as windows in both the Table API and SQL require
 information about the notion of time and its origin. Therefore, tables can offer
 logical time attributes for indicating time and accessing corresponding timestamps
 in table programs.[1]
This mean Window can only be defined over a time attribute column.
You need define a rowtime in your source just like (UserActionTime is a long field, you don't need convert it to Timestamp):
Table table = tEnv.fromDataStream(stream, "Username, Data, UserActionTime.rowtime");
See more information in below document:

Best, JingsongLee

------------------------------------------------------------------
From:Yu Yang <[hidden email]>
Send Time:2019年6月5日(星期三) 14:57
To:user <[hidden email]>
Subject:can flink sql handle udf-generated timestamp field

Hi, 

I am trying to use Flink SQL to do aggregation on a hopping window. In the data stream, we store the timestamp in long type. So I wrote a UDF 'FROM_UNIXTIME' to convert long to Timestamp type. 

  public static class TimestampModifier extends ScalarFunction {
    public Timestamp eval(long t) {
      return new Timestamp(t);
    }
    public TypeInformation<?> getResultType(Class<?>[] signature) {
      return Types.SQL_TIMESTAMP;
    }
  }

With the above UDF, I wrote the following query, and ran into  "ProgramInvocationException: The main method caused an error: Window can only be defined over a time attribute column". 
Any suggestions on how to resolve this issue? I am using Flink 1.8 for this experiment. 

my sql query: 

select  keyid, sum(value) 
from ( 
   select FROM_UNIXTIME(timestampMs) as ts, key.id as keyid, value 
   from orders) 
 group by HOP(ts, INTERVAL ‘10’ second, INTERVAL ‘30’ second), keyid 

flink exception: 

org.apache.flink.client.program.ProgramInvocationException: The main method caused an error: Window can only be defined over a time attribute column.
at org.apache.flink.client.program.PackagedProgram.callMainMethod(PackagedProgram.java:546)
at org.apache.flink.client.program.PackagedProgram.invokeInteractiveModeForExecution(PackagedProgram.java:421)
at org.apache.flink.client.program.ClusterClient.run(ClusterClient.java:423)
at org.apache.flink.client.cli.CliFrontend.executeProgram(CliFrontend.java:813)
at org.apache.flink.client.cli.CliFrontend.runProgram(CliFrontend.java:287)
at org.apache.flink.client.cli.CliFrontend.run(CliFrontend.java:213)
at org.apache.flink.client.cli.CliFrontend.parseParameters(CliFrontend.java:1050)
at org.apache.flink.client.cli.CliFrontend.lambda$main$11(CliFrontend.java:1126)
at org.apache.flink.runtime.security.NoOpSecurityContext.runSecured(NoOpSecurityContext.java:30)
at org.apache.flink.client.cli.CliFrontend.main(CliFrontend.java:1126)
Caused by: org.apache.flink.table.api.ValidationException: Window can only be defined over a time attribute column.
at org.apache.flink.table.plan.rules.datastream.DataStreamLogicalWindowAggregateRule.getOperandAsTimeIndicator$1(DataStreamLogicalWindowAggregateRule.scala:85)
at org.apache.flink.table.plan.rules.datastream.DataStreamLogicalWindowAggregateRule.translateWindowExpression(DataStreamLogicalWindowAggregateRule.scala:99)
at org.apache.flink.table.plan.rules.common.LogicalWindowAggregateRule.onMatch(LogicalWindowAggregateRule.scala:66)
at org.apache.calcite.plan.AbstractRelOptPlanner.fireRule(AbstractRelOptPlanner.java:319)
at org.apache.calcite.plan.hep.HepPlanner.applyRule(HepPlanner.java:559)
at org.apache.calcite.plan.hep.HepPlanner.applyRules(HepPlanner.java:418)

Regards, 
-Yu

Reply | Threaded
Open this post in threaded view
|

Re: can flink sql handle udf-generated timestamp field

Yu Yang
In reply to this post by Yu Yang
+flink-user

On Wed, Jun 5, 2019 at 9:58 AM Yu Yang <[hidden email]> wrote:
Thanks for the reply!  In flink-table-planner, TimeIndicatorTypeInfo is an internal class that cannot be referenced from application. I got "cannot find symbol" error when I tried to use it. I have also tried to use " SqlTimeTypeInfo.getInfoFor(Timestamp.class) " as return type for my udf type info. With that, I got the same  "Window can only be defined over a time attribute column" error as before. 

On Wed, Jun 5, 2019 at 4:41 AM Lee tinker <[hidden email]> wrote:
Hi Yu Yang:
When you want to use time on window, the type of time should be right according to flink.  We can see you return a Types.SQL_TIMESTAMP in your UDF. This type should be TimeIndicatorTypeInfo.PROCTIME_INDICATOR or  TimeIndicatorTypeInfo.ROWTIME_INDICATOR instead of Types.SQL_TIMESTAMP according to your time type(proctime or rowtime). You can try it again by using it.

Yu Yang <[hidden email]> 于2019年6月5日周三 下午2:57写道:
Hi, 

I am trying to use Flink SQL to do aggregation on a hopping window. In the data stream, we store the timestamp in long type. So I wrote a UDF 'FROM_UNIXTIME' to convert long to Timestamp type. 

  public static class TimestampModifier extends ScalarFunction {
    public Timestamp eval(long t) {
      return new Timestamp(t);
    }
    public TypeInformation<?> getResultType(Class<?>[] signature) {
      return Types.SQL_TIMESTAMP;
    }
  }

With the above UDF, I wrote the following query, and ran into  "ProgramInvocationException: The main method caused an error: Window can only be defined over a time attribute column". 
Any suggestions on how to resolve this issue? I am using Flink 1.8 for this experiment. 

my sql query: 

select  keyid, sum(value) 
from ( 
   select FROM_UNIXTIME(timestampMs) as ts, key.id as keyid, value 
   from orders) 
 group by HOP(ts, INTERVAL ‘10’ second, INTERVAL ‘30’ second), keyid 

flink exception: 

org.apache.flink.client.program.ProgramInvocationException: The main method caused an error: Window can only be defined over a time attribute column.
at org.apache.flink.client.program.PackagedProgram.callMainMethod(PackagedProgram.java:546)
at org.apache.flink.client.program.PackagedProgram.invokeInteractiveModeForExecution(PackagedProgram.java:421)
at org.apache.flink.client.program.ClusterClient.run(ClusterClient.java:423)
at org.apache.flink.client.cli.CliFrontend.executeProgram(CliFrontend.java:813)
at org.apache.flink.client.cli.CliFrontend.runProgram(CliFrontend.java:287)
at org.apache.flink.client.cli.CliFrontend.run(CliFrontend.java:213)
at org.apache.flink.client.cli.CliFrontend.parseParameters(CliFrontend.java:1050)
at org.apache.flink.client.cli.CliFrontend.lambda$main$11(CliFrontend.java:1126)
at org.apache.flink.runtime.security.NoOpSecurityContext.runSecured(NoOpSecurityContext.java:30)
at org.apache.flink.client.cli.CliFrontend.main(CliFrontend.java:1126)
Caused by: org.apache.flink.table.api.ValidationException: Window can only be defined over a time attribute column.
at org.apache.flink.table.plan.rules.datastream.DataStreamLogicalWindowAggregateRule.getOperandAsTimeIndicator$1(DataStreamLogicalWindowAggregateRule.scala:85)
at org.apache.flink.table.plan.rules.datastream.DataStreamLogicalWindowAggregateRule.translateWindowExpression(DataStreamLogicalWindowAggregateRule.scala:99)
at org.apache.flink.table.plan.rules.common.LogicalWindowAggregateRule.onMatch(LogicalWindowAggregateRule.scala:66)
at org.apache.calcite.plan.AbstractRelOptPlanner.fireRule(AbstractRelOptPlanner.java:319)
at org.apache.calcite.plan.hep.HepPlanner.applyRule(HepPlanner.java:559)
at org.apache.calcite.plan.hep.HepPlanner.applyRules(HepPlanner.java:418)

Regards, 
-Yu
Reply | Threaded
Open this post in threaded view
|

Re: can flink sql handle udf-generated timestamp field

Yu Yang
In reply to this post by JingsongLee
Hi Jingsong,

Thanks for the reply! The following is our code snippet for creating the log stream.  Our messages are in thrift format. We use a customized serializer for serializing/deserializing messages ( see  https://github.com/apache/flink/pull/8067 for the implementation) . Given that, how shall we define a time attribute column?  We'd like to leverage customized serializer to figure out column names as much as possible. 

    ThriftDeserializationSchema deserializationSchema =
        new ThriftDeserializationSchema(CustomerOrders.class, ThriftCodeGenerator.SCROOGE);

    FlinkKafkaConsumer kafkaConsumer =
        new FlinkKafkaConsumer(“customer_orders”, deserializationSchema, m10n05Properties);

    tableEnv.registerDataStream(“orders”, kafkaConsumer);

Regards,
-Yu

On Wed, Jun 5, 2019 at 11:15 PM JingsongLee <[hidden email]> wrote:
Hi @Yu Yang:
Time-based operations such as windows in both the Table API and SQL require
 information about the notion of time and its origin. Therefore, tables can offer
 logical time attributes for indicating time and accessing corresponding timestamps
 in table programs.[1]
This mean Window can only be defined over a time attribute column.
You need define a rowtime in your source just like (UserActionTime is a long field, you don't need convert it to Timestamp):
Table table = tEnv.fromDataStream(stream, "Username, Data, UserActionTime.rowtime");
See more information in below document:

Best, JingsongLee

------------------------------------------------------------------
From:Yu Yang <[hidden email]>
Send Time:2019年6月5日(星期三) 14:57
To:user <[hidden email]>
Subject:can flink sql handle udf-generated timestamp field

Hi, 

I am trying to use Flink SQL to do aggregation on a hopping window. In the data stream, we store the timestamp in long type. So I wrote a UDF 'FROM_UNIXTIME' to convert long to Timestamp type. 

  public static class TimestampModifier extends ScalarFunction {
    public Timestamp eval(long t) {
      return new Timestamp(t);
    }
    public TypeInformation<?> getResultType(Class<?>[] signature) {
      return Types.SQL_TIMESTAMP;
    }
  }

With the above UDF, I wrote the following query, and ran into  "ProgramInvocationException: The main method caused an error: Window can only be defined over a time attribute column". 
Any suggestions on how to resolve this issue? I am using Flink 1.8 for this experiment. 

my sql query: 

select  keyid, sum(value) 
from ( 
   select FROM_UNIXTIME(timestampMs) as ts, key.id as keyid, value 
   from orders) 
 group by HOP(ts, INTERVAL ‘10’ second, INTERVAL ‘30’ second), keyid 

flink exception: 

org.apache.flink.client.program.ProgramInvocationException: The main method caused an error: Window can only be defined over a time attribute column.
at org.apache.flink.client.program.PackagedProgram.callMainMethod(PackagedProgram.java:546)
at org.apache.flink.client.program.PackagedProgram.invokeInteractiveModeForExecution(PackagedProgram.java:421)
at org.apache.flink.client.program.ClusterClient.run(ClusterClient.java:423)
at org.apache.flink.client.cli.CliFrontend.executeProgram(CliFrontend.java:813)
at org.apache.flink.client.cli.CliFrontend.runProgram(CliFrontend.java:287)
at org.apache.flink.client.cli.CliFrontend.run(CliFrontend.java:213)
at org.apache.flink.client.cli.CliFrontend.parseParameters(CliFrontend.java:1050)
at org.apache.flink.client.cli.CliFrontend.lambda$main$11(CliFrontend.java:1126)
at org.apache.flink.runtime.security.NoOpSecurityContext.runSecured(NoOpSecurityContext.java:30)
at org.apache.flink.client.cli.CliFrontend.main(CliFrontend.java:1126)
Caused by: org.apache.flink.table.api.ValidationException: Window can only be defined over a time attribute column.
at org.apache.flink.table.plan.rules.datastream.DataStreamLogicalWindowAggregateRule.getOperandAsTimeIndicator$1(DataStreamLogicalWindowAggregateRule.scala:85)
at org.apache.flink.table.plan.rules.datastream.DataStreamLogicalWindowAggregateRule.translateWindowExpression(DataStreamLogicalWindowAggregateRule.scala:99)
at org.apache.flink.table.plan.rules.common.LogicalWindowAggregateRule.onMatch(LogicalWindowAggregateRule.scala:66)
at org.apache.calcite.plan.AbstractRelOptPlanner.fireRule(AbstractRelOptPlanner.java:319)
at org.apache.calcite.plan.hep.HepPlanner.applyRule(HepPlanner.java:559)
at org.apache.calcite.plan.hep.HepPlanner.applyRules(HepPlanner.java:418)

Regards, 
-Yu

Reply | Threaded
Open this post in threaded view
|

Re: can flink sql handle udf-generated timestamp field

Fabian Hueske-2
Hi Yu,

When you register a DataStream as a Table, you can create a new attribute that contains the event timestamp of the DataStream records.
For that, you would need to assign timestamps and generate watermarks before registering the stream:

FlinkKafkaConsumer kafkaConsumer =
        new FlinkKafkaConsumer(“customer_orders”, deserializationSchema, m10n05Properties);

// create DataStream from Kafka consumer
DataStream<CustomerOrders> orders = env.addSource(kafkaConsumer);
// assign timestamps with a custom timestamp assigner & WM generator
DataStream<CustomerOrders> ordersWithTS = orders.assignTimestampsAndWatermarks(new YourTimestampAssigner());

// register DataStream as Table with ts as timestamp which is automatically extracted (see [1] for how to map POJO fields and [2] for timestamps)
tableEnv.registerDataStream("custom_orders", ordersWithTS, "userName, ..., ts.rowtime");

Hope this helps,
Fabian


Am Do., 6. Juni 2019 um 08:48 Uhr schrieb Yu Yang <[hidden email]>:
Hi Jingsong,

Thanks for the reply! The following is our code snippet for creating the log stream.  Our messages are in thrift format. We use a customized serializer for serializing/deserializing messages ( see  https://github.com/apache/flink/pull/8067 for the implementation) . Given that, how shall we define a time attribute column?  We'd like to leverage customized serializer to figure out column names as much as possible. 

    ThriftDeserializationSchema deserializationSchema =
        new ThriftDeserializationSchema(CustomerOrders.class, ThriftCodeGenerator.SCROOGE);

    FlinkKafkaConsumer kafkaConsumer =
        new FlinkKafkaConsumer(“customer_orders”, deserializationSchema, m10n05Properties);

    tableEnv.registerDataStream(“orders”, kafkaConsumer);

Regards,
-Yu

On Wed, Jun 5, 2019 at 11:15 PM JingsongLee <[hidden email]> wrote:
Hi @Yu Yang:
Time-based operations such as windows in both the Table API and SQL require
 information about the notion of time and its origin. Therefore, tables can offer
 logical time attributes for indicating time and accessing corresponding timestamps
 in table programs.[1]
This mean Window can only be defined over a time attribute column.
You need define a rowtime in your source just like (UserActionTime is a long field, you don't need convert it to Timestamp):
Table table = tEnv.fromDataStream(stream, "Username, Data, UserActionTime.rowtime");
See more information in below document:

Best, JingsongLee

------------------------------------------------------------------
From:Yu Yang <[hidden email]>
Send Time:2019年6月5日(星期三) 14:57
To:user <[hidden email]>
Subject:can flink sql handle udf-generated timestamp field

Hi, 

I am trying to use Flink SQL to do aggregation on a hopping window. In the data stream, we store the timestamp in long type. So I wrote a UDF 'FROM_UNIXTIME' to convert long to Timestamp type. 

  public static class TimestampModifier extends ScalarFunction {
    public Timestamp eval(long t) {
      return new Timestamp(t);
    }
    public TypeInformation<?> getResultType(Class<?>[] signature) {
      return Types.SQL_TIMESTAMP;
    }
  }

With the above UDF, I wrote the following query, and ran into  "ProgramInvocationException: The main method caused an error: Window can only be defined over a time attribute column". 
Any suggestions on how to resolve this issue? I am using Flink 1.8 for this experiment. 

my sql query: 

select  keyid, sum(value) 
from ( 
   select FROM_UNIXTIME(timestampMs) as ts, key.id as keyid, value 
   from orders) 
 group by HOP(ts, INTERVAL ‘10’ second, INTERVAL ‘30’ second), keyid 

flink exception: 

org.apache.flink.client.program.ProgramInvocationException: The main method caused an error: Window can only be defined over a time attribute column.
at org.apache.flink.client.program.PackagedProgram.callMainMethod(PackagedProgram.java:546)
at org.apache.flink.client.program.PackagedProgram.invokeInteractiveModeForExecution(PackagedProgram.java:421)
at org.apache.flink.client.program.ClusterClient.run(ClusterClient.java:423)
at org.apache.flink.client.cli.CliFrontend.executeProgram(CliFrontend.java:813)
at org.apache.flink.client.cli.CliFrontend.runProgram(CliFrontend.java:287)
at org.apache.flink.client.cli.CliFrontend.run(CliFrontend.java:213)
at org.apache.flink.client.cli.CliFrontend.parseParameters(CliFrontend.java:1050)
at org.apache.flink.client.cli.CliFrontend.lambda$main$11(CliFrontend.java:1126)
at org.apache.flink.runtime.security.NoOpSecurityContext.runSecured(NoOpSecurityContext.java:30)
at org.apache.flink.client.cli.CliFrontend.main(CliFrontend.java:1126)
Caused by: org.apache.flink.table.api.ValidationException: Window can only be defined over a time attribute column.
at org.apache.flink.table.plan.rules.datastream.DataStreamLogicalWindowAggregateRule.getOperandAsTimeIndicator$1(DataStreamLogicalWindowAggregateRule.scala:85)
at org.apache.flink.table.plan.rules.datastream.DataStreamLogicalWindowAggregateRule.translateWindowExpression(DataStreamLogicalWindowAggregateRule.scala:99)
at org.apache.flink.table.plan.rules.common.LogicalWindowAggregateRule.onMatch(LogicalWindowAggregateRule.scala:66)
at org.apache.calcite.plan.AbstractRelOptPlanner.fireRule(AbstractRelOptPlanner.java:319)
at org.apache.calcite.plan.hep.HepPlanner.applyRule(HepPlanner.java:559)
at org.apache.calcite.plan.hep.HepPlanner.applyRules(HepPlanner.java:418)

Regards, 
-Yu

Reply | Threaded
Open this post in threaded view
|

Re: can flink sql handle udf-generated timestamp field

Yu Yang
Thank you Fabian!  We will try the approach that you suggest. 

On Thu, Jun 6, 2019 at 1:03 AM Fabian Hueske <[hidden email]> wrote:
Hi Yu,

When you register a DataStream as a Table, you can create a new attribute that contains the event timestamp of the DataStream records.
For that, you would need to assign timestamps and generate watermarks before registering the stream:

FlinkKafkaConsumer kafkaConsumer =
        new FlinkKafkaConsumer(“customer_orders”, deserializationSchema, m10n05Properties);

// create DataStream from Kafka consumer
DataStream<CustomerOrders> orders = env.addSource(kafkaConsumer);
// assign timestamps with a custom timestamp assigner & WM generator
DataStream<CustomerOrders> ordersWithTS = orders.assignTimestampsAndWatermarks(new YourTimestampAssigner());

// register DataStream as Table with ts as timestamp which is automatically extracted (see [1] for how to map POJO fields and [2] for timestamps)
tableEnv.registerDataStream("custom_orders", ordersWithTS, "userName, ..., ts.rowtime");

Hope this helps,
Fabian


Am Do., 6. Juni 2019 um 08:48 Uhr schrieb Yu Yang <[hidden email]>:
Hi Jingsong,

Thanks for the reply! The following is our code snippet for creating the log stream.  Our messages are in thrift format. We use a customized serializer for serializing/deserializing messages ( see  https://github.com/apache/flink/pull/8067 for the implementation) . Given that, how shall we define a time attribute column?  We'd like to leverage customized serializer to figure out column names as much as possible. 

    ThriftDeserializationSchema deserializationSchema =
        new ThriftDeserializationSchema(CustomerOrders.class, ThriftCodeGenerator.SCROOGE);

    FlinkKafkaConsumer kafkaConsumer =
        new FlinkKafkaConsumer(“customer_orders”, deserializationSchema, m10n05Properties);

    tableEnv.registerDataStream(“orders”, kafkaConsumer);

Regards,
-Yu

On Wed, Jun 5, 2019 at 11:15 PM JingsongLee <[hidden email]> wrote:
Hi @Yu Yang:
Time-based operations such as windows in both the Table API and SQL require
 information about the notion of time and its origin. Therefore, tables can offer
 logical time attributes for indicating time and accessing corresponding timestamps
 in table programs.[1]
This mean Window can only be defined over a time attribute column.
You need define a rowtime in your source just like (UserActionTime is a long field, you don't need convert it to Timestamp):
Table table = tEnv.fromDataStream(stream, "Username, Data, UserActionTime.rowtime");
See more information in below document:

Best, JingsongLee

------------------------------------------------------------------
From:Yu Yang <[hidden email]>
Send Time:2019年6月5日(星期三) 14:57
To:user <[hidden email]>
Subject:can flink sql handle udf-generated timestamp field

Hi, 

I am trying to use Flink SQL to do aggregation on a hopping window. In the data stream, we store the timestamp in long type. So I wrote a UDF 'FROM_UNIXTIME' to convert long to Timestamp type. 

  public static class TimestampModifier extends ScalarFunction {
    public Timestamp eval(long t) {
      return new Timestamp(t);
    }
    public TypeInformation<?> getResultType(Class<?>[] signature) {
      return Types.SQL_TIMESTAMP;
    }
  }

With the above UDF, I wrote the following query, and ran into  "ProgramInvocationException: The main method caused an error: Window can only be defined over a time attribute column". 
Any suggestions on how to resolve this issue? I am using Flink 1.8 for this experiment. 

my sql query: 

select  keyid, sum(value) 
from ( 
   select FROM_UNIXTIME(timestampMs) as ts, key.id as keyid, value 
   from orders) 
 group by HOP(ts, INTERVAL ‘10’ second, INTERVAL ‘30’ second), keyid 

flink exception: 

org.apache.flink.client.program.ProgramInvocationException: The main method caused an error: Window can only be defined over a time attribute column.
at org.apache.flink.client.program.PackagedProgram.callMainMethod(PackagedProgram.java:546)
at org.apache.flink.client.program.PackagedProgram.invokeInteractiveModeForExecution(PackagedProgram.java:421)
at org.apache.flink.client.program.ClusterClient.run(ClusterClient.java:423)
at org.apache.flink.client.cli.CliFrontend.executeProgram(CliFrontend.java:813)
at org.apache.flink.client.cli.CliFrontend.runProgram(CliFrontend.java:287)
at org.apache.flink.client.cli.CliFrontend.run(CliFrontend.java:213)
at org.apache.flink.client.cli.CliFrontend.parseParameters(CliFrontend.java:1050)
at org.apache.flink.client.cli.CliFrontend.lambda$main$11(CliFrontend.java:1126)
at org.apache.flink.runtime.security.NoOpSecurityContext.runSecured(NoOpSecurityContext.java:30)
at org.apache.flink.client.cli.CliFrontend.main(CliFrontend.java:1126)
Caused by: org.apache.flink.table.api.ValidationException: Window can only be defined over a time attribute column.
at org.apache.flink.table.plan.rules.datastream.DataStreamLogicalWindowAggregateRule.getOperandAsTimeIndicator$1(DataStreamLogicalWindowAggregateRule.scala:85)
at org.apache.flink.table.plan.rules.datastream.DataStreamLogicalWindowAggregateRule.translateWindowExpression(DataStreamLogicalWindowAggregateRule.scala:99)
at org.apache.flink.table.plan.rules.common.LogicalWindowAggregateRule.onMatch(LogicalWindowAggregateRule.scala:66)
at org.apache.calcite.plan.AbstractRelOptPlanner.fireRule(AbstractRelOptPlanner.java:319)
at org.apache.calcite.plan.hep.HepPlanner.applyRule(HepPlanner.java:559)
at org.apache.calcite.plan.hep.HepPlanner.applyRules(HepPlanner.java:418)

Regards, 
-Yu