Hey Flink users, Currently using Flink 1.7.2 with a job using FlinkKafkaProducer with its write semantic set to Semantic.EXACTLY_ONCE. When there is a job failure and restart (in our case from checkpoint timeout), it begins
a failure loop that requires a cancellation and resubmission to fix. The expected and desired outcome should be a recovery from failure and the job restarts successfully. Some digging revealed an issue where the class loader closes before the connection to
kafka is fully terminated resulting in a NoClassDefFoundError. A description of what is happening has already been described here:
https://heap.io/blog/engineering/missing-scala-class-noclassdeffounderror, though we are experiencing this with kafka, not Redis: 5/3/19 3:14:18.780 PM
2019-05-03 15:14:18,780 ERROR org.apache.kafka.common.utils.KafkaThread - Uncaught exception in thread 'kafka-producer-network-thread | producer-80': java.lang.NoClassDefFoundError: org/apache/kafka/clients/NetworkClient$1 at org.apache.kafka.clients.NetworkClient.processDisconnection(NetworkClient.java:658) at org.apache.kafka.clients.NetworkClient.handleDisconnections(NetworkClient.java:805) at org.apache.kafka.clients.NetworkClient.poll(NetworkClient.java:520) at org.apache.kafka.clients.producer.internals.Sender.run(Sender.java:226) at org.apache.kafka.clients.producer.internals.Sender.run(Sender.java:163) at java.lang.Thread.run(Thread.java:748) Collapse date_hour = 15 Interestingly, this only happens when we extend the FlinkKafkaProducer for the purposes of setting the write semantic to EXACTLY_ONCE. When running with the default FlinkKafkaProducer (using Semantic.AT_LEAST_ONCE),
the class loader has no issues disconnecting the kafka client on job failure, and the job recovers just fine. We are not doing anything particularly strange in our extended producer as far as I can tell: public class
CustomFlinkKafkaProducer<IN> extends FlinkKafkaProducer<IN> { public
CustomFlinkKafkaProducer(Properties properties, String topicId, AvroKeyedSerializer<IN> serializationSchema) { super( topicId, serializationSchema, properties, Optional.of(new FlinkFixedPartitioner<>()),
Semantic.EXACTLY_ONCE, DEFAULT_KAFKA_PRODUCERS_POOL_SIZE); } public static Properties getPropertiesFromBrokerList(String brokerList) { […] } } |
It is a blocker for exactly once support from flink kafka producer. This issue reported and closed. but still reproducible On Mon, May 6, 2019 at 10:20 AM Slotterback, Chris <[hidden email]> wrote:
Thanks
Rohan |
Thanks for reporting this issue Chris. It looks indeed as if FLINK-10455 has not been fully fixed. I've reopened it and linked this mailing list thread. If you want, then you could write to the JIRA thread as well. What would be super helpful is if you manage to create a reproducing example for further debugging. Cheers, Till On Tue, May 7, 2019 at 4:04 PM Rohan Thimmappa <[hidden email]> wrote:
|